[AIX] fc(fscsi) LINK ERROR 발생 시 확인 방법

반응형

서버 내 FC LINK ERROR 관련 에러가 발생했을 때 아래와 같이 확인하면 된다.

 

1. 현재 상황 확인

# errpt
IDENTIFIER     TIMESTAMP     T     C     RESOURCE_NAME     DESCRIPTION
DC73C03A     0906100423     T     S     fscsi2     SOFTWARE PROGRAM ERROR
4B436A3D     0906100423     T     H     fscsi2     LINK ERROR

2. 에러 상세 확인

# errpt -aj 4B436A3D
LABEL:               FCP_ERR4
IDENTIFIER:                4B4365A3D
Date/Time:                Wed Sep 6 09:50:33 GMT+09:00 2023
Sequence Number:                265263
Machine Id:                00F6423D4C00
Node Id:                KBJD1
Class:                H
Type:                TEMP
WPAR:               Global
Resource Name:               fscsi2
Resource Class:               driver
Resource Type:               efscsi
Location:               U78A0.001.DNWK1B8-P1-C4-T1

Description
LINK ERROR

               Recommended Actions
               PERFROM PROBLEM DETERMINATION PROCEDURES

temp성 에러지만 해당 문제를 트러블 슈팅하기 위해서는 해당 fc 패스로 들어오는 외부 볼륨 상태(enable/disable) 및 fc 포트 상태 점검이 필요하다.

 

3. fc 상태 점검

# lsdev -Cc adapter
ent0      Available 00-00 2-Port 10/100/1000 Base-TX PCI-Express Adapter (14104003)
ent1      Available 00-01 2-Port 10/100/1000 Base-TX PCI-Express Adapter (14104003)
ent2      Available 04-00 2-Port 10/100/1000 Base-TX PCI-Express Adapter (14104003)
ent3      Available 04-01 2-Port 10/100/1000 Base-TX PCI-Express Adapter (14104003)

ent4      Available    EtherChannel  /  IEEE 802.3ad Link Aggregation
fcs0      Available 01-00 8Gb FC PCI Express Adapter (df1000f114108a03)

fcs1      Available 01-01 8Gb FC PCI Express Adapter (df1000f114108a03)
fcs2      Available 03-00 8Gb FC PCI Express Adapter (df1000f114108a03)  //  fscsi2
fcs3      Available 03-01 8Gb FC PCI Express Adapter (df1000f114108a03)
sissas0   Available 02-00 PCI-X266 Planar 3Gb SAS Adapter
sissas1   Available 05-00 PCI-X266 Planar 3Gb SAS Adapter

usbhc0    Available 07-08 USB Host Controller (33103500)
usbhc1    Available 07-09 USB Host Controller (33103500)
vsa0      Available       LPAR Virtual Serial Adapter


# lscfg -vpl fcs2 | grep -i Location
                              Hardware Location Code......U78A0.001.DNWK1B8-P1-C4-T1  // 2번 과정에서 봤던 errpt 내용 상 Location과 동일.
                              Physical Location: U78A0.001.DNWK1B8-P1-C4-T1


# fcstat -D fcs2 | grep -i attention
Attention Type: Link Up  // 링크가 살아 있다는 뜻


# lspath 또는 powermt display paths (히다찌 또는 EMC 스토리지 일 때 해당됨) 명령어로 fscsi2로 들어오는 외부 볼륨 path 상태가 online인지 offline인지 확인해야 함

 

반응형

댓글

Designed by JB FACTORY